[Q21-Q36] Real NSE5_FSM-6.3 dumps - Real Fortinet dumps PDF in here [May-2024]

Share

Real NSE5_FSM-6.3 dumps - Real Fortinet dumps PDF in here [May-2024]

Realistic TestPDF NSE5_FSM-6.3 Dumps PDF - 100% Passing Guarantee

NEW QUESTION # 21
A FortiSIEM supervisor at headquarters is struggling to keep up with an increase of EPS (Events Per Second) being reported across the enterprise.
What components should an administrator consider deploying to assist the supervisor with processing data?

  • A. Collector
  • B. Agent
  • C. Worker
  • D. Supervisor

Answer: C


NEW QUESTION # 22
Which FortiSIEM components can do performance availability and performance monitoring?

  • A. Supervisor only
  • B. Collectors only
  • C. Supervisor and workers only
  • D. Supervisor, worker, and collector

Answer: D


NEW QUESTION # 23
If a performance rule is triggered repeatedly due to high CPU use. what occurs m the incident table?

  • A. The incident status changes to Repeated and the First Seen and Last Seen times are updated
  • B. A new incident is created each time the rule is triggered, and the First Seen and Last Seen times are updated.
  • C. A new incident is created based an the Rule Frequency value, and the First Seen and Last Seen times are updated
  • D. The Incident Count value increases, and the First Seen and Last Seen tomes update

Answer: D


NEW QUESTION # 24
What are the four possible incident status values?

  • A. Active, auto cleared, manual, false positive
  • B. Active, dosed, cleared, open
  • C. Active, closed, manual, resolved
  • D. Active, cleared, cleared manually, system cleared

Answer: D


NEW QUESTION # 25
Which protocol is almost always required for the FortiSIEM GUI discovery process?

  • A. Telnet
  • B. Syslog
  • C. WMI
  • D. SNMP

Answer: D


NEW QUESTION # 26
What are the minimum memory requirements for the FortiSIEM supervisor virtual appliance, when the proprietary flat file database is used?

  • A. 32GB RAM
  • B. 16G8 RAM
  • C. 64G8 RAM
  • D. 24GB RAM

Answer: D


NEW QUESTION # 27
If events are grouped by Event Receive Time, Reporting IP, and User attributes in FortiSIEM, how many results will be displayed?

  • A. Two results will be displayed
  • B. Unique attributes cannot be grouped
  • C. Eight results will be displayed
  • D. Four results will be displayed

Answer: B


NEW QUESTION # 28
In the advanced analytical rules engine in FortiSIEM, multiple subpatterms can be referenced using which three operation? (Choose three.)

  • A. NOT
  • B. OR
  • C. ELSE
  • D. AND
  • E. FOLLOWED_BY

Answer: B,D,E


NEW QUESTION # 29
What is a prerequisite for a FortiSIEM supervisor with a worker deployment, using the proprietary flat file database?

  • A. The CMDB database must be on NFS
  • B. The archive mount must be on a local disk
  • C. The event database must be on a local disk
  • D. The event database must be on NFS

Answer: D


NEW QUESTION # 30
An administrator wants to search for events received from Linux and Windows agents.
Which attribute should the administrator use in search filters, to view events received from agents only?

  • A. External Event Receive Agents
  • B. External Event Receive Raw Logs
  • C. External Event Receive Protocol
  • D. Event Received Proto Agents

Answer: C


NEW QUESTION # 31
A FortiSIEM administrator wants to restrict a network administrator to running searches for only firewall devices.
Under role management, which option does the FortiSIEM administrator need to configure to achieve this scenario?

  • A. Data Conditions
  • B. UI Access
  • C. CMDB Report Conditions

Answer: A


NEW QUESTION # 32
Which three ports can be used to send Syslogs to FortiSIEM? (Choose three.)

  • A. TCP 1470
  • B. UDP 9999
  • C. UDP 162
  • D. TCP 514
  • E. UDP 514

Answer: A,D,E


NEW QUESTION # 33
What do the yellow stars listed in the Monitor column indicate?

  • A. A yellow star indicates that a metric was not applied during discovery and, therefore, FortiSIEM was unable to collect data.
  • B. A yellow star indicates that a metric was applied during discovery, but data collection has not started
  • C. A yellow star indicates that a metric was applied during discovery, and data has been collected successfully
  • D. A yellow star indicates that a metric was applied during discovery, but FortiSIEM is unable to collect data

Answer: B


NEW QUESTION # 34
Which two export methods are available for FortiSIEM analytics results? (Choose two.)

  • A. HTML
  • B. csv
  • C. PNG
  • D. PDF

Answer: B,D


NEW QUESTION # 35
In FortiSIEM enterprise licensing mode, if the link between the collector and data center FortiSIEM cluster a down what happens?

  • A. The collector processes stop, and events are dropped
  • B. The collector drops incoming events like syslog, but slops performance collection
  • C. The collector buffers events
  • D. The collector continues performance collection of devices, but stops receiving syslog

Answer: C


NEW QUESTION # 36
......

Verified NSE5_FSM-6.3 dumps Q&As Latest NSE5_FSM-6.3 Download: https://braindumps.testpdf.com/NSE5_FSM-6.3-practice-test.html